Pike v. Trinity Industries, Inc.
Pike v. Trinity Industries, Inc.
Opinion of the Court
ORDER
Plaintiff Charles Pike was the passenger in a Ford F-150 truck when it went off the road and struck a guardrail- in Lake County, Florida on October 29, 2010. The end terminal of the guardrail, which had been improperly repaired in 2009 by the Florida Department of Transportation (“FDOT”) following an earlier accident, entered the truck cabin through the passenger side wheel well causing terrible injuries to Pike, a young man whose medical treatment included a below-the-knee leg amputation.
In this lawsuit, Pike claims that the guardrail system manufacturer, Trinity Highway Products, LLC and its parent company, Trinity Industries, Inc. (together, “Trinity”), failed to warn FDOT that its guardrail system could fail if not repaired in compliance with the original installation instructions. Trinity has moved for summary judgment on several grounds. Upon review, the Court holds as a matter of law that FDOT is a “sophisticated user” of guardrail systems, familiar with the protocols for their installation, inspection and repair. Therefore, Trinity had no duty to warn FDOT of the danger of negligent repairs, and summary judgment is due to be entered in Trinity’s favor.
I. Standard of Review
Summary judgment is appropriate where “there is no genuine dispute as to any material fact and the movant is entitled to judgment as a matter of law.” Fed.R.Civ.P. 56(a). “An issue of fact is ‘material’ if, under the applicable substantive law, it might affect the outcome of the case. An issue of fact is ‘genuine’ if the record taken as a whole could lead a rational trier of fact to find for the nonmov-ing party.” Harrison v. Culliver, 746 F.3d 1288, 1298 (11th Cir. 2014) (citation omitted). The Court “must view all evidence and reasonable inferences in the light most favorable” to the non-moving party; however “the mere existence of a scintilla of evidence in support of [that party’s] position will be insufficient.” Miller’s Ale
This case is brought under the Court’s diversity jurisdiction
II. Background
In 2007 Trinity was awarded a contract with the State of Florida for the installation of Trinity’s ET-Plus end terminal system and guardrail at the intersection of State Road 33 and Groveland Airport Road in Lake County, Florida. A state-approved contractor installed the guardrail. Trinity guardrail systems are not “retail” products; rather, they are sold exclusively to municipalities, states, and other government entities or their contractors. See Doc. 135, Ex. U (Deposition of Trinity Vice-President of International Sales and corporate representative Brian Smith) at Transcript (“Tr.”) 17. Trinity’s ET-Plus end terminal system is comprised of over fifty component parts shipped as a self-contained package with everything needed to assemble the entire system except the tools.
Developed and patented by Texas A & M University’s Transportation Institute (an agency of the State of Texas), and manufactured and sold by Trinity through a licensing agreement, a key feature of the ET-Plus end terminal system is that, upon impact, the end piece (or extruder head) is pushed by the vehicle along the first section of guardrail until it hits a self-releasing cable, which then causes the guardrail to feed through the extruder head, flattening and deflecting away from the vehicle. Doc. 135, Ex. D (Deposition of Roger P.J. Bligh, Ph.D., Texas Transportation Institute research engineer) at Tr. 17-18.
The cable anchor bracket (PC-704A5 ) is secured to the rail panel by inserting the*1196 protruding hooks on the bracket into the slots in the rail panel. It is locked into place by pulling the bracket toward the impact end of the unit.
Doc. 135, Ex. F (ET-Plus Installation Instructions) at p. 15. Trinity manufactures several variations of the ET-Plus system to accommodate various state standards. See Doc. 135, Ex. L (Deposition of Don J. Gripne, Trinity representative and trainer) at Tr. 14. The ET-Plus Installation Instructions reference variances in the materials list and installation procedures depending on a given state’s specifications and preferred options. See Doc. 135, Ex. F (ET-Plus Installation Instructions) at pp. 1-6.
In addition to the Trinity Installation Instructions, FDOT has its own materials used to train employees about guardrail installation, inspection and maintenance. According to FDOT, “[g]uardrail systems comprise the rail that runs down the road and the end treatment that protects vehicles from end-on hits.” Doc. 135, Ex. 0 (FDOT Computer Based Training (“CBT”) Slides) at Guardrail Introduction slide 6. The training slides explain that the focus is mainly on end treatments, “because they are the most complicated part of the system and require the most rigorous inspection.” Id. FDOT explains that the first step in guardrail installation is to “[r]eview [the guardrail’s] [d]esign [standards and manufacturer’s specifications” ahd further instructs that the “installation of end treatment varies according to treatment used.” Id. at Guardrail Installation slides 1, 11. The audio that accompanies the training slides explains that “[a] guardrail will protect the public only if it [is] properly installed and inspected.” Doc. 135, Ex. P (FDOT CBT Transcript) at Tr. 8. FDOT explains that “[o]nce the installation is completed, the maintenance of the terminals is now the responsibility of the State or Highway agency.” Id. at Tr. 41. The FDOT materials include instructions on the installation of various types of end treatments, using the ET-2000 as an example of a parallel end treatment.
Guardrail repairs are supervised by an FDOT employee using either FDOT laborers or prison inmates for the work crew and are then inspected by an FDOT supervisor. Doc. 135, Ex. B. (Deposition of FDOT engineer Philip Maggio) at Tr. 21-25. Maintenance and repair are discussed in the ET-Plus installation instructions, which explains that inventory should be taken following an accident to determine which parts may be reusable and which may need to be replaced. Doc. 135, Ex. F at p. 19. The Trinity instructions state that the anchor cable and bracket should be checked for damage and that, once re
Trinity also offers training to state departments of transportation and contractors whenever requested. Doc. 135, Ex. L (Gripne Deposition) at Tr. 34-35. Trinity representative Don Gripne conducted a training session with approximately 50 FDOT maintenance employees on November 6, 2008 in Lake City. See Doc. 135, Ex. M (course roster), Doc. 135, Ex. L. (Gripne Deposition) at Tr. 36-40. Trinity’s training sessions typically include handouts of the relevant installation manuals and design drawings, and a slide presentation about the various products used by that state, including photographs of the guardrail systems and their components. Id. at Tr. 8, 47-50. Gripne testified that the training sessions are tailored to the needs of each particular state and the design drawings used in the slides he showed at the FDOT training session were created by the state, depicting the guardrail systems used in Florida. Id. at Tr. 47.
Trinity has a trailer with examples of the various products that it sometimes brings to training sessions to provide hands-on demonstrations of how the systems work. Gripne brought the trailer to the 2008 Lake City training session; samples of the ET system and the SRT system were on the trailer.
FDOT’s faulty repairs remained unnoticed and were still in place at the time the truck Pike was riding in struck the end terminal in October 2010. Because the end terminal used a cable anchor system that was bolted to the guardrail instead of being fastened by self-releasing hooks, the guardrail could not feed through the ex-truder head and flatten and slide away from the impact; instead, the end terminal and guardrail entered the passenger side of the truck, nearly severing Pike’s leg on impact.
III. Legal Proceedings
In April 2011, Pike sued both FDOT and Trinity Highway Products, LLC in state court bringing claims of negligence as to FDOT for the faulty repair on the guard
IY. Discussion
In Counts VII through X of his amended complaint (Doc. 54), Pike brings claims of negligence and strict liability against Trinity based on failure to warn, alleging that Trinity failed to warn FDOT personnel that parts from other guardrail systems could not be combined with Trinity’s ET-Plus guardrail system without compromising the system’s integrity.
While Florida law recognizes claims of negligent and strict liability failure to warn,
There are countless skilled operations such as the rigging of scaffolding, which involve otherwise non-dangerous products in potentially dangerous situations. A manufacturer of such a product should be able to presume mastery of the basic operation. The more so when, as here, the manufacturer affirmatively and successfully limits the market of its product to professionals. In such a case, the manufacturer should not be burdened with the often difficult task of providing instructions on how to properly perform the basic operation.
Antcliff v. State Employees Credit Union, 414 Mich. 624, 327 N.W.2d 814, 821 (1982). See also, Parker v. Schmiede Machine and Tool Corp., 445 Fed.Appx. 231, 234 (11th Cir. 2011) (explaining that under Georgia law, the sophisticated user or learned intermediary doctrine relieves a manufacturer of liability for failure to warn where members of the profession to whom the product is sold are generally aware of hazards known to the trade); Carmical v. Bell Helicopter Textron, Inc., 117 F.3d 490, 495 (11th Cir. 1997) (holding that helicopter manufacturer had no duty under Georgia law to warn pilot that loss of lubrication to gearshaft could result in engine failure where pilot knew that maintenance of an oil lubricated engine required lubrication to engine); Powell Duffryn Terminals, Inc. v. Calgon Carbon Corp., 4 F.Supp.2d 1198, 1203 (S.D.Ga. 1998) (holding that chemical storage terminal was a sophisticated user under Georgia law to whom Calgon had no duty to warn that its cleaning product, would ignite when used near stored chemicals); Fernandez v. Tamko Bldg. Products, Inc., 2 F.Supp.3d 854, 864, 2014 WL 905115, *6 (M.D.La. March 7, 2014) (“Louisiana does not hold that a manufacturer is compelled to warn sophisticated purchasers of dangers of which the buyer either knows or should be aware.”) (citation omitted); Duane v. Oklahoma Gas & Elec. Co., 833 P.2d 284, 287 (Okl. 1992) (holding that oil suppliers had no duty to warn of danger to commercial customer whose negligence or oversight resulted in explosion that injured its employee).
Trinity argues (and pled as an affirmative defense) that FDOT is a sophisti
However, the issue here is not the engineering and construction of the guardrail system (although FDOT is familiar enough with those that it has its own design drawings and state standards that Trinity is required to follow), but its repair and maintenance, matters that FDOT handles exclusively. As discussed above, FDOT has created an entire set of training materials devoted to guardrails, discussing the various types and how to install, maintain, repair and inspect them. See Doc. 135, Ex. O, P. The FDOT materials explain that “FDOT is responsible for maintaining guardrail systems so they function correctly” (Doc. 135, Ex. O (FDOT CBT Slides) at Guardrail Introduction slide 5); it explains that end treatments “are the most complicated part of the system and require the most rigorous inspection” (Id. at Guardrail Introduction slide 6) and directs employees to consult the manufacturer’s instructions (Id. at Guardrail Introduction slide 2). The FDOT materials include step-by-step instructions with photos for installing various systems, including the ET-2000 (the self-releasing cable system manufactured by Trinity that is the earlier generation of the ET-Plus). Doc. 135, Ex. O.
FDOT accepts its responsibility for the repair of the guardrail system at issue and admits that it failed in its responsibility. FDOT Operations Engineer Philip Maggio testified that the inspector who signed off on the 2009 repair (James Hudson) should have noticed that the end terminal was not right. Doc. 135, Ex. B (Maggio Deposition) at Tr. 111. Hudson’s supervisor, FDOT field manager James Tyson, also testified that he did not know why Hudson didn’t notice that the wrong cable anchor bracket was used. Doc. 135, Ex. J (Tyson Deposition) at Tr. 13, 16. Hudson himself, who had worked for FDOT for approximately ten years at the time of the 2009 repair, testified that the repair protocol includes walking the length of the guardrail to ensure that it is all assembled correctly. Doc. 135, Ex. C (Hudson Deposition) at Tr. 36. Hudson had attended the 2008 Trinity training
Hudson said, “I guess it was an oversight” that the end terminal was misas-sembled during the 2009 repair — and it was “hard for [him] to believe” that the wrong bracket was there and that he “didn’t catch it.” Id. at Tr. 32. Hudson said somebody must have picked up the wrong part (Id. at Tr. 34-35), revealing that he as an inspector knew there was a right way and a wrong way to assemble the end terminal and that bolting a cable anchor bracket to the rail on an energy-absorbing self-release system like an ET-Plus was the wrong way.
Notwithstanding the FDOT training protocols, Richard Houle, the FDOT employee who handled the 2009 repair, testified that “in the real world” employees just go to the back of the FDOT warehouse and look for parts that look like the parts that are broken and piece it all back together. Doc. 135, Ex. K at Tr. 45-46. Houle, a six-year employee of FDOT, testified that his formal training consisted of shadowing other employees who taught him how to repair guardrails by essentially putting them back the way they were before. Id. at Tr. 22. If a part cannot be located in the FDOT warehouse yard,
Without a doubt, Houle did not follow Trinity’s instructions or FDOT protocol when .making the 2009 repairs and his failure to do so resulted in serious injuries to Pike.
Here, Houle’s superiors are experienced in guardrail maintenance, repair and inspection and understood the importance of proper assembly even if Houle did not. FDOT engineer Maggio testified as to his knowledge of the two types of guardrail systems and those systems are carefully described in the FDOT computer based training materials. See Doc. 135, Ex. B (Maggio Deposition) at Tr. 33, Ex. O (FDOT CBT slides), Ex. P (FDOT CBT transcript). FDOT presumably purchased the ET-Plus guardrail system because of its energy-absorbing feature and FDOT was in a position to understand that the system cannot function properly if the self releasing cable anchor bracket — a key component of the system — is bolted to the rail. Indeed, FDOT’s own operations engineer and supervisor both agreed it was a mistake to secure the ET-Plus extruder head using a bolted on cable anchor system in the 2009 repair. Doc. 135, Ex. B (Maggio Deposition) at Tr. 35-36, 47-48,
FDOT was aware that end terminals are complex and need to be repaired in accordance with manufacturer’s instructions. The FDOT supervisor and engineer testified that the design drawings should be consulted and that inspections and maintenance would ensure that repairs are done correctly. Even if the FDOT staff involved in the actual 2009 repair failed to fully appreciate the complexity of the complete design of the ET-Plus guardrail system, they at least had an understanding that there were two types of systems — one with a parallel end treatment, and one with a flared end treatment. The guardrail FDOT assembled after the 2009 accident at the corner of Groveland Airport Road and State Road 33 was neither.
On this record, the Court finds Pike has failed to come forward-with more than a scintilla of evidence to rebut Trinity’s showing that FDOT was a sophisticated user of the ET-Plus guardrail system.
Y. Conclusion
For his own reasons, Pike gave up a seemingly well-taken negligence claim against FDOT in favor of a design defect claim against Trinity that he later abandoned. He elected to proceed solely on a failure to warn theory. However, as a matter of law, Trinity had no duty to warn FDOT what it already well knew: that it should avoid using parts from other guardrail systems when repairing the ET-Plus guardrail end terminals. Trinity’s Motion for summary judgment (Doc. 135) is granted and judgment is due to be entered in favor of Trinity Industries, Inc. and Trinity Highway Products, LLC as to Pike’s failure to warn claims, Counts VII, VIH, IX, X of his amended complaint (Doc. 54). As Pike has abandoned his design defect claims, Counts I, II, III, IV, V and VI of his amended complaint (Doc. 54) are dismissed with prejudice. The Clerk shall enter judgment accordingly and close the file.
. Pike is a citizen and resident of Florida. Trinity Industries, Inc. is a Delaware corporation with its principal place of business in Texas. Trinity Highway Products, LLC is a Delaware limited liability company with its principal place of business in Texas. Trinity Industries owns 100% of the interest in Trinity Highway Products, LLC. See Docs. 9, 54, 55 & 56 (certificate of interested parties, revised amended complaint, defendants' answers to revised amended complaint).
. While much of the technical detail comes from Trinity personnel or experts -it hired, Pike has not presented evidence to dispute these points. In fact, the only evidentiary material Pike submitted in opposition to summary judgment were excerpts of five of the depositions of Trinity and FDOT personnel that Trinity filed in support of summary judgment, and excerpts of two other depositions of Trinity personnel. See Docs. 142 & 143.
. According to Trinity's Brian Smith, if multiple units are ordered, the guardrail and head pieces are shipped in groups, but the other parts and assembly hardware are individually packaged and shipped for every unit. See Doc. 135, Ex. U.atTr. 25.
. All such energy-absorbing guardrail end treatments approved for use on U.S. highways use similar self-releasing cables to function properly. Doc. 135, Ex. H (Affidavit of Trinity expert, Malcolm Ray) at ¶ 14.
. Although the parts are identified by part number in the Installation Instructions, and a description of the parts listed by part number
. As described by Brian Smith, Trinity’s corporate representative, the ET-2000 is an earlier generation of the ET-Plus, but the anchor assembly design is the same. Doc. 135, Ex. U at Tr. 12-13. In the FDOT materials, the ET-Plus is described as a related product to the ET-2000 that installs the same way; the user of the computer training program is directed to refer to the Florida Design Standards for the product if there are any questions about the installation. Doc. 135, Ex. P (FDOT CBT Transcript) at Tr. 8-9.
. Whereas the ET-2000 and ET-Plus are examples of energy absorbing "parallel” end treatments (where the rail is parallel to the road and the end treatment is designed to absorb the vehicle’s momentum by bending the rail and breaking the posts, Doc. 135, Ex. P (FDOT CBT transcript) at Tr. 4), the SRT system, which is also manufactured by Trinity, is an example of a non-energy absorbing "flared” end treatment. In a flared end treatment (so called because the end treatment is curved away from the road), the end piece is not expected to move and the cable anchor assembly is bolted to the rail. See Doc. 135, Ex. R (Report of Trinity expert, Malcolm Ray) at 12; Ex. P (FDOT CBT Transcript) at Tr. 4. When a vehicle hits a properly installed flared end treatment, the vehicle should break the post and bend the rail, coming to a safe, gradual stop. Doc. 135, Ex. P (FDOT CBT transcript) at Tr. 4. The SRT-350 version of the SRT system is a common end treatment on Florida roadways. Doc. 135, Ex. B (Mag-gio Deposition) at Tr. 44-45; Ex. U (Smith Deposition) atTr. 57.
. Gripne, who is assigned to Trinity’s marketing department, said the training sessions generally also include demonstrations of Trinity's newest product lines so a given state can
. In his report, authored subsequent to his affidavit, Ray opined that a piece of cable was also from the ET-Plus. See Doc. 135, Ex. R at 9. However, Trinity representative Don Gripne said of the piece of cable, "I can’t tell you whether it is [a Trinity product] or it is not ... [b]ecause anybody can manufacture ... that piece of cable.” Doc. 135, Ex. L at Tr. 71-72. Even if originally from the ET-Plus, the presence of the cable would not change the analysis because the cable was affixed to a cable anchor assembly that was bolted to the rail, a method undisputedly inconsistent with the installation or repair of an ET-Plus system.
. Pike’s design defect claim alleged that a 2005 change in the design of the ET-Plus caused the guardrail to get stuck inside the chute attached to the end terminal thereby preventing the guardrail from flattening and sliding away from the impact. See Doc. 54 at ¶¶ 31-43.
. By agreement of the parties, the discovery gathered for the state court case was available for the parties’ use in this federal case.
. The Court incorporates by reference the entire transcript of the May 9, 2014 oral argument (Doc. 149).
. Count VII is negligent failure to warn against Trinity Highway Products; Count VIII is strict liability failure to warn against Trinity Highway Products; Count IX is negligent failure to warn against Trinity Industries and Count X is strict liability failure to warn against Trinity Industries.
.See, e.g., Faddish v. Buffalo Pumps, 881 F.Supp.2d 1361, 1370 (S.D.Fla. 2012) (explaining difference under Florida law between negligent failure to warn, which focuses on the defendant's conduct, and strict liability failure to warn, which focuses on the product and consumer expectations); Giddens v. Denman Rubber Mfg. Co., 440 So.2d 1320, 1322 (Fla. 5th DCA 1983) (quoting comment (h) to section 402(A) of the Restatement of Torts (Second) for the proposition that a product which is otherwise safe for normal handling may be required to include a warning if danger may result from a particular use of the product).
. Plaintiff cites Parker v. Schmiede Machine and Tool Corp., 445 Fed.Appx. 231, 235-36 (11th Cir. 2011) for the proposition that the determination of whether a customer is a sophisticated user or learned intermediary is a question of fact for a jury. See Doc. 142 (plaintiff's brief) at p. 9. However, Parker does not so hold. In Parker, the Eleventh Circuit discussed the evidence supporting a finding that the industrial consumer was a sophisticated user of the defendant’s chemical, discussed the plaintiffs failure to put forward sufficient evidence to the contrary, and affirmed the district court’s entry of summary judgment in favor the manufacturer on the grounds that its industrial customer was a
. Though the parties agree that Florida recognizes the learned intermediary and sophisticated user doctrines, there are few Florida cases discussing it outside of the context of pharmaceutical or chemical products and the Court has mentioned those deemed useful to the discussion. Some of these cases appear to apply the doctrine implicitly. See, e.g., Shell Oil Co. v. Harrison, 425 So.2d 67 (Fla. 1st DCA 1983) (reversing and remanding for entry of judgment in favor of Shell which discharged its duty to warn retail consumers of danger of its chemical where intermediary (who formulated, packaged and labeled product for retail sale) was aware of danger). Both parties rely on non-Florida cases as persuasive authority regarding the contours of the doctrine and the Court likewise finds their explanations to be helpful and consistent with Florida law.
. Hudson did not recall that Gripne provided any instruction on guardrail installation but his memory of what took place was not clear and his recollection was that the training session lasted only "about half an hour[;] [m]aybe an hour,” versus the four hours that Gripne’s paperwork indicates. See Docs. 135, Ex. C (Hudson Deposition) at Tr.- 21; Ex. M (course roster, listing Hudson’s name on page 3), showing 4 hour course titled "Guardrail Training (proper installation and maintenance).”
. During FDOT’s 2009 repair, it was an anchor cable such as is used by the SRT-350 that was bolted to the rail, preventing the ET-Plus extruder head from continuing to slide down the rail during the Pike crash. Doc. 135, Ex. H (Ray Affidavit) at ¶ 18. Thus, FDOT personnel had indiscriminately and improperly used parts of two entirely different systems.
.Hudson recalled the 2009 repair but thought the paperwork was signed by Houle and not himself, creating some question as to whether Hudson signed off as the inspector. Doc. 135, Ex. C, Tr. 29, 39-41, 45-47. Hudson agreed he did inspect and sign off on the repairs following the Pike accident, which were also misassembled. Id. at Tr. 31-32.
. Hudson also said this is a dangerous intersection and that he has inspected this guardrail on other occasions in the past. There are apparently no records other than for the 2009 repair. Doc. 135, Ex. C (Hudson Deposition) at Tr. 45-46. While not a material dispute, contrary to Houle's testimony on this point, Trinity’s expert Malcolm Ray reviewed pjiotos taken from the 2009 accident (the one predating Pike's) and reports that the ET-Plus functioned as designed in that accidenlj, with 18 feet of guardrail having been fed through and deflected by the ET-Plus extruder ; head (as opposed to the 18 inches fed through in the Pike crash). Doc. 135, Ex. R (Ray Report) at 21, 13.
. Though it is not an issue before the Court, had the case gone to trial, Trinity would have sought to assign fault elsewhere too and planned to list the driver of the pick-up along with FDOT on the verdict form as Fabre defendants. See Doc. 55 at ¶ 132 & Doc. 56 at ¶ 132 (Trinity's Affirmative Defenses).
. As Texas Transportation Institute’s engineer, Roger Bligh explained, "I am not sure how you would ... confuse the parts if ... you’re at all knowledgeable ... in the field ... of these systems.” Doc. 135, Ex. D (Bligh Deposition) at Tr. 89. In response to the question as to whether he had had any conversations about the possibility that parts could be improperly and mistakenly co-mingled, Bligh responded: "[Y]ou're making, I think, inappropriate assumptions about our industry perhaps.” He elaborated: “[Tjhese systems are ... designed and engineered for a specific reason and a specific purpose to meet a certain standard and ... the end user is ... a transportation department, ... and they’re ... going to have knowledgeable installers and contractors that ... are putting these systems in.” Id. at Tr. 89-90. He further explained that just as the installers would consult the manuals, so too would those performing the repairs to ensure the system continues to conform to "the requirements and ... specifications of the user agency ... whose engineers are ... prescribing ... a certain product at a ... given location.” Id. at 90-91.
. Pike points to testimony from William Bur-ney, Trinity’s Vice-President of Domestic Sales and Marketing, to suggest that Trinity was aware that "co-mingling" of parts was a known problem that Trinity had a duty to address. Doc. 143, Ex. F (Burney Deposition) at Tr. 47-48. But Burney later explains that the "co-mingling” issue of which he spoke had to do with co-mingling of other energy-absorbing system parts that look alike, not the co-mingling of parts from entirely different systems. Id. at 56-57. The cable anchor treatment FDOT mistakenly bolted to the rail connecting to the ET-Plus extruder head is part of a flared end treatment (such as the SRT), not part of an energy-absorbing system such as the ET-Plus. Id. See also, Doc. 135, Ex. B (FDOT engineer Maggio Deposition) at Tr. 44-45, 52 (explaining the difference between the SRT system, a “bolted on model,” and the ET-Plus, "a hanging model”).
Pike also devotes much of his brief to a discussion of the need for decals or warning labels to advise FDOT staff as to which parts go with which system, contending repeatedly that Trinity's trainer, Don Gripne, agreed with its position. As plaintiff's counsel conceded at oral argument, that reading takes Gripne's testimony out of context. The record is undisputed that FDOT and its staff recognized the difference between the two basic types of guardrail systems and FDOT was a sophisticated user for all the reasons stated above. Trinity therefore had no duty to warn that parts from one type of system should not be used to repair the other type. FDOT already knew that. Thus, this is not a case where a jury must decide whether warnings provided them were sufficient and reasonable under the law. Cf., Union Carbide Corp. v. Aubin, 97 So.3d 886, 898-901 (Fla. 3d DCA 2012) (explaining in an asbestos case that the sufficiency and reasonableness of warnings are fact questions unless the warnings are 'accurate, clear, and unambiguous,’ and further noting the learned intermediary doctrine could be a defense where the evidence was not in conflict with regard to the knowledge and sophistication of the interme-
. Because the Court finds FDOT is a sophisticated user of guardrail systems to whom Trinity had no duty to warn about the danger of using other guardrail parts while repairing an ET-Plus system, the Court does not reach Trinity’s alternative arguments as to why summary judgment should be entered in its favor on these counts, nor does the Court address the other pretrial motions by Trinity (mainly seeking to exclude other evidence put forward by Pike). Docs. 132, 133, 134, 136 are therefore moot.