Delman, Inc. v. Connel
Opinion of the Court
The petitioner, by certiorari, seeks to review a determination of the board of standards and appeals which had affirmed the decision of the superintendent of buildings in refusing to issue a certificate of occupancy for petitioner’s premises, 558 Madison avenue, Manhattan.
The building, as it now stands, is seven stories in height with a frontage of about thirty-two feet and a depth of about seventy-six feet. It is seventy-five feet high. The building is non-fireproof brick and was erected in 1878-1879, at that time being five stories in height.
The present means of exit are by an interior stair and an exterior fire escape which terminates in a counterweighted stair to a rear
The certificate of occupancy was sought in 1928, to permit the use of the upper five stories for light manufacturing purposes. The alleged occupancy is distributed as follows:
Persons.
First story.......................................... 11
Second story........................................ 12
Third story......................................... 7
Fourth story........................................ 8
Fifth story.......................................... 8
Sixth story......................................... 10
Seventh story................... 8
The certificate of occupancy was refused for various specified reasons, only two of which are material here, since the petitioner expressed its readiness to comply with all remaining specifications. The two items, the subject of the appeal, are:
(a) Building must be fireproof and comply with the provisions of section 270 of the Labor Law.
(b) All windows in exterior walls must be fireproof and self-closing and area of glass must not exceed 720 square inches.
The building, as stated, was originally five stories in height, devoted to office use. Some time after 1921 the usage was changed to factory occupancy. In 1926 two stories were added to the then existing building, making it seven stories and seventy-five feet in height.
The sole question for determination is whether the building is a new building within the purview of section 270 of the Labor Law, or an old building within the purview of section 271. If the latter, then the building complies with the law and the certificate should be granted. If not, the certificate was properly refused.
Section 270 of the Labor Law, among other things, provides: “Ho factory shall be conducted in a building erected after October first, nineteen hundred and thirteen, which is more than one story in height unless such building shall conform to the following requirements:
“1. Fireproof construction. All buildings more than four stories in height shall be fireproof.”
The petitioner claims that its building is one erected prior to
On the side of strict technical construction much can be said in favor of petitioner’s claim. Were the question one of interpretation of some other law, less essentially and primarily connected with the safeguarding of workers from the danger of fire inherent in factory buildings, I might be inclined to agree with the petitioner. But here the intent of the law is clear and of paramount importance in interpreting the statute.
Individual property rights, sacred as they are, must succumb to the common weal. Measures fashioned to lessen casualties, to decrease the hazards of fire, to promote safety and to safeguard the public, must be elastically interpreted to gain their objective, rather than so compressed as to weaken or destroy their efficacy. One of the capital purposes of government will fail if nice distinctions are allowed to emasculate or defeat such laws.
Were it possible for the legislators in enacting the various provisions of the Labor Law to have adopted standard requirements for all existing buildings they would have done so. Certainly the necessity for such requirements existed with even greater force as to older buildings such as this, erected at a time when archaic construction and lack of safety devices contributed to the greater risk of human life. But the legislators could not do this because such a law, completely changing the character of buildings previously erected, would have encountered constitutional obstructions.
They were forced to leave existing buildings substantially the same, although as to such existing buildings even greater reason existed for complete renovation. They reluctantly yielded to constitutional limitations. The barrier of limitation protected only the building as it stood. If that building were changed and enlarged it ceased to be the building immune, because and only because of its prior erection, from the salutary requirements of the Labor Law.
Such a situation is disclosed here. The building, as such, is one erected after 1913. Its character has been substantially changed. If petitioner’s contention were pushed to its logical conclusion, then a building erected prior to 1913 could be “ altered/’
I am not unmindful of the fact that in the past departmental opinions, statements and actions may have misled, and undoubtedly did mislead, this petitioner into the belief that its building was one Which was subject only to the requirements of section 271 of the Labor Law, and it may have relied upon this assumption and acted to its present damage. But there can be no estoppel against the public.
I must assume that the board, because of its experience, has considered the possibility of such variation and conclude that nothing but strict and literal compliance will suffice. I concern myself with the sole question of interpretation of the law. Its working details have been specifically intrusted to the board.
The motion to dismiss the order of certiorari is granted, but without costs.